OxyCorder 401

The OxyCorder is primarily used to measure dissolved oxygen in photosynthesis research. Therefore the impedance of three independent input channels is preset for different electrode sizes: 4 MΩ (Channel 1), 1.3 MΩ (Channel 2), and 33 kW (Channel 3 - for large electrodes, as bare platinum-silver). The fourth input channel enables voltage reading. The QxyCorder is supplied with OxyWin software that controls polarization voltage of the electrodes (0 to 1000 mV, two 10 bit A/D converters) and also enables displaying and analyzing the measured data.


Any of the three input channels can be alternatively configured for voltage reading; 30 measurements per second is the maximum. The instrument can also replace chart recorders. Three TTL outputs (minimum timing step is 1 ms) allow controlling external devices; e.g., shutters or flash-lamps. Data reading can be synchronized with controlling signals. For example, the oxygen bursts occurring in the organisms of oxygenic photosynthesis after an exposure to actinic flashes can be measured with a preset delay between the flash and the measurement.

Lab use of the oxycorder

Pricing

Download

Software
Nothing

Documents
Magnetic Stirrer Manual
Type: PDF
Language: English
Size: 111 KB


OxyCorder Manual
Type: PDF
Language: English
Size: 907 KB


Thermoregulator Manual
Type: PDF
Language: English
Size: 174 KB


Gas Mixing System Manual
Type: PDF
Language: English
Size: 929 KB


Gas Mixing System GMS 150 - List of References
Type: PDF
Language: English
Size: 612 KB


Other Instruments

Mass Spectrometer MS GAS-100

Mass Spectrometer MS GAS-100 is a compact bench-top gas analyzer with mass spectrometry detection is designed for complex analyses of gases and volatiles including isotopes, solvents and volatile organics.


PlanTherm PT 100

PlanTherm PT 100 is a complete system for fast and easy estimation of heat stability of plants. It includes the measuring unit, magnetic stirrer, thermoregulator, and mini-computer in one compact case.


Gas Mixing System GMS 150

High-precision GMS 150 can produce mixtures of up to 4 different gases. The flows of the individual input gases are measured by thermal mass flow meters and adjusted by integrated mass flow controllers. It can be used as a stand-alone instrument or in a system with the PSI Photobioreactors.


Spectrometer SM 9000

Spectrometer SM 9000 was developed for advanced high-resolution, fiber optic spectroscopy applications in the UV/VIS to NIR range. Fast recording can capture as many as 100 spectra per second with data resolution of 16 bits.


OxyCorder 401

The primary application of the instrument is the polarographic measurement of dissolved oxygen by a Clark electrode.


Video Gallery